Integration Model to CinC Generation: Difference between revisions

From PHENOM Portal Knowledgebase
Jump to navigation Jump to search
mNo edit summary
 
(9 intermediate revisions by 2 users not shown)
Line 2: Line 2:


== Create a UoP ==
== Create a UoP ==
 
First, create a UoP to be used by a UoP Instance within the model. A new UoP can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the necessary data.
Firstly, the user needs to create a UoP to be used by a UoP Instance within the model. A new UoP can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the necessary data.
[[File:Generate_-_CreateUoP.png|border|800x800px]]
[[File:Generate_-_CreateUoP.png|none|thumb|800x800px]]
Once the user has created their UoP it is now time to create the UoP Instance that will be used in CinC generation. This UoP Instance is going to be very important for later steps.
Once the user has created their UoP it is now time to create the UoP Instance that will be used in CinC generation. This UoP Instance is going to be very important for later steps.


== Create a UoP Instance ==
== Create a UoP Instance ==
Similarly, A new UoP Instance can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the required data .
Similarly, new UoP Instance can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the required data .
[[File:Generate_-_CreateUoPInstance2.png|none|thumb|800x800px]]
[[File:Generate_-_CreateUoPInstance2.png|border|800x800px]]
Next, the user needs to create a Main Program to be used during CinC. This is the Main Program that will house our UoP Instance and should be selected during creation.


== Create a Context ==
== Create a Context ==
a. Add UoP Instance to the context.
The context is a visual diagram of the interactions between a UoP and the configurable elements of CinC.
Find the UoP Instance in the navigation tree and drag it onto the context.
[[File:Generate - CreateContext.png|none|thumb|800px]]
 
# Add UoP Instance to the context.
b. Add a Transporter to the context.
## Find the UoP Instance in the navigation tree and select it
From the left side of the diagram find the transporter block and drag it onto the diagram.
## Drag it onto the context.
 
# Add a Transporter to the context.
c. Create a Transport Channel
## In the horizontal toolbar on the left side of the diagram find and select the transporter block
With the transporter block selected, on the right side find the Transport Channel control and click on the '+' to add a new channel, give the channel a name and click the save icon. Once the save completes, click on the transport channel drop down and select the name of the channel you just created.
## Drag the transporter block onto the diagram.
# Create a Transport Channel
## With the transporter block selected, on the right side find the Transport Channel control and click on the '+' to add a new channel
## Give the channel a name and click the save icon.  
## Once the save completes, click on the transport channel drop down and select the name of the channel you just created.
# Connect the blocks
##Select the Uop Instance block in the diagram
## click on the up arrow at the upper right corner of the block and drag it over to the transporter block.
## A popup dialog will allow you to select the UoP port to connect to the transporter, select the port from the drop down list and click on save.
#Commit the changes.
##Click the Commit button under the heading Model on the diagram tool bar.  This saves the changes to the Integration Model (IM) elements but does NOT save the diagram.
# Save the diagram
##click the middle disk icon under diagram in order to save the layout of the elements in the diagram.  This saves the layout of the items in the diagram but does NOT save changes to the Integration or Deployment models that may have been made while editing the diagram elements.


d. Connect the blocks
== Create a Main ==
Select the Uop Instance block in the diagram, click on the up arrow at the upper right corner of the block and drag it over to the transporter block.  A popup dialog will allow you to select the UoP port to connect to the transporter, select the port from the drop down list and click on save.
The Main Program represents the executable program containing one (or more) UoPs and CinC.
 
#A new Main Program can be created by selecting the corresponding option in the 'Create>Deployment' dropdown and then saving after inputting the needed data including the UoP Instance.
e. Commit the changes.
Click the Commit button under the heading Model on the diagram tool bar.  This saves the changes to the Integration Model (IM) elements but does NOT save the diagram.
f. Save the diagram
click the middle disk icon under diagram in order to save the layout of the elements in the diagram
 
 
== Create a main ==
A new Main Program can be created by selecting the corresponding option in the 'Create>Deployment' dropdown and then saving after inputting the needed data including the UoP Instance.
[[File:Generate_-_CreateMainProgram2.png|none|thumb|800x800px]]
[[File:Generate_-_CreateMainProgram2.png|none|thumb|800x800px]]


== Add a TPM ==
== Add a TPM ==
within the Main detail page, after saving the main click on the Create TPM button. Give the tpm a name ('tpm' is fine) and click the save button.  Commit the changes to the main by clicking the disk icon in the upper right.
The transport protocol module is responsible for the serialization and deserialization of messages and their transport from one TPM to another or another system.  
 
'''This step is optional as PHENOM will generate a UDP TPM by default.'''


== Generate CINC ==
[[File:Generate - MainCreateTPM2.png|thumb|none|800px]]
a. Next the user needs to open the 'Generate' section and click on the CinC submenu.
# Within the Main detail page, after saving the main, click on the Create TPM button.
b. The user should select 'CinC' as the artifact.
# Give the TPM a name ('tpm' is fine).
c. Select the version of CinC you would like to generate
# Click the save button.   
d. Select include CinC Source and choose Yes.
# Commit the changes to the main by clicking the disk icon in the upper right.
e. Select the Main and UoP Instances for the context we created above and make sure they are both checked
f. Select the appropriate license.
g. Click on the Generate button and a zip file will be createdThe .zip file will contain the cinc source, the data modeled FACE types used by the UoP and the CinC configuration files. Save the file, extr


Finally, click the 'Generate' button after setting up the config and selection to generate FACE 3.0 CinC and a .zip file will be created for download.
== Generate CinC ==
# Next the user needs to open the 'Generate' section and click on the CinC submenu.
# The user should select 'CinC' as the artifact.
# Select the version of CinC you would like to generate
# Select include CinC Source and choose Yes.
# Select the Main and UoP Instances for the context we created above and make sure they are both checked
# Select the appropriate license.
# Click on the Generate button and a zip file will be created.  The .zip file will contain the cinc source, the data modeled FACE types used by the UoP and the CinC configuration files. Save the file and extract the generated code.
[[File:Generate_-_CinC.png|none|thumb|800x800px]]
[[File:Generate_-_CinC.png|none|thumb|800x800px]]

Latest revision as of 09:53, 26 September 2024

This sample workflow will lead the user to generate FACE 3 CinC after creating necessary Mains, UoP Instances, and UoPs.

Create a UoP

First, create a UoP to be used by a UoP Instance within the model. A new UoP can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the necessary data. Once the user has created their UoP it is now time to create the UoP Instance that will be used in CinC generation. This UoP Instance is going to be very important for later steps.

Create a UoP Instance

Similarly, new UoP Instance can be created by selecting the corresponding option in the 'Create>Integration' dropdown and then saving after inputting the required data .

Create a Context

The context is a visual diagram of the interactions between a UoP and the configurable elements of CinC.

  1. Add UoP Instance to the context.
    1. Find the UoP Instance in the navigation tree and select it
    2. Drag it onto the context.
  2. Add a Transporter to the context.
    1. In the horizontal toolbar on the left side of the diagram find and select the transporter block
    2. Drag the transporter block onto the diagram.
  3. Create a Transport Channel
    1. With the transporter block selected, on the right side find the Transport Channel control and click on the '+' to add a new channel
    2. Give the channel a name and click the save icon.
    3. Once the save completes, click on the transport channel drop down and select the name of the channel you just created.
  4. Connect the blocks
    1. Select the Uop Instance block in the diagram
    2. click on the up arrow at the upper right corner of the block and drag it over to the transporter block.
    3. A popup dialog will allow you to select the UoP port to connect to the transporter, select the port from the drop down list and click on save.
  5. Commit the changes.
    1. Click the Commit button under the heading Model on the diagram tool bar. This saves the changes to the Integration Model (IM) elements but does NOT save the diagram.
  6. Save the diagram
    1. click the middle disk icon under diagram in order to save the layout of the elements in the diagram. This saves the layout of the items in the diagram but does NOT save changes to the Integration or Deployment models that may have been made while editing the diagram elements.

Create a Main

The Main Program represents the executable program containing one (or more) UoPs and CinC.

  1. A new Main Program can be created by selecting the corresponding option in the 'Create>Deployment' dropdown and then saving after inputting the needed data including the UoP Instance.

Add a TPM

The transport protocol module is responsible for the serialization and deserialization of messages and their transport from one TPM to another or another system.

This step is optional as PHENOM will generate a UDP TPM by default.

  1. Within the Main detail page, after saving the main, click on the Create TPM button.
  2. Give the TPM a name ('tpm' is fine).
  3. Click the save button.
  4. Commit the changes to the main by clicking the disk icon in the upper right.

Generate CinC

  1. Next the user needs to open the 'Generate' section and click on the CinC submenu.
  2. The user should select 'CinC' as the artifact.
  3. Select the version of CinC you would like to generate
  4. Select include CinC Source and choose Yes.
  5. Select the Main and UoP Instances for the context we created above and make sure they are both checked
  6. Select the appropriate license.
  7. Click on the Generate button and a zip file will be created. The .zip file will contain the cinc source, the data modeled FACE types used by the UoP and the CinC configuration files. Save the file and extract the generated code.